E45-457 · Vibration and Mechanical Stress · Level Sensor · ★★
Vibration loosens the screws of the sensor junction box cover; the cover opens and rainwater enters, causing a short circuit
[Mechanism] Vibration decays the cover screw preload until it loosens; the cover gap opens and water enters, causing a short circuit.
[Calculation] Vibration loosens the cover screws each month and opens a 0.5mm gap; water ingress makes the insulation drop sharply and short-circuits.
[Design Deficiency] The cover used screws only, with no anti-loosening and no sealing.
① Anti-loosening screws: apply threadlocker to the cover screws → prevent loosening
② Add a gasket: fit a sealing gasket to the cover → waterproof
③ Quick latch: use quick-release latches instead of screws → secure the cover
④ Protective cover: add an outer cover → block water
⑤ Regular inspection: inspect the cover tightness → early correction
⑥ Water-ingress monitoring: alarm on leakage inside the box → early detection
⑦ Cover-opening verification: confirm by measuring the gap and water ingress under vibration → data confirmation
⑧ Selection standardization: write cover protection into the spec → control at the source
GB/T 4208-2017 Degrees of protection provided by enclosures (IP code)