E45-468 · Vibration and Mechanical Stress · Displacement Sensor · ★★
Vibration loosens and shifts the permanent magnet inside the magnetic sensor; the magnetic-field reference changes and the output drifts
[Mechanism] Vibration loosens the magnet's adhesive or fails its fastening and shifts the magnet; the air-gap field distribution changes and the sensitivity deviates.
[Calculation] A 0.5mm magnet displacement changes the working air-gap field by 3%, causing an error of 0.5% FS.
[Design Deficiency] The permanent magnet relied only on adhesive, with no mechanical fixing.
① Mechanical fixing: add a clamp or press fit to the magnet → prevent displacement
② Potting lock: pot the assembly to lock the magnet → prevent movement
③ Adhesive reinforcement: add adhesive to the bond → strengthen
④ Vibration-resistant selection: choose fully encapsulated magnetic-circuit packaging → improve stability
⑤ Periodic calibration: check zero drift → early correction
⑥ Displacement monitoring: alarm on the magnetic-field reference → early detection
⑦ Displacement verification: confirm by measuring the magnetic field under vibration → data confirmation
⑧ Selection standardization: write magnet fixing into the assembly spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test