Knowledge Base › Electrical Sensor Error Case › Incorrect Media Corrosion Compatibility Perforates and Leaks the Diaphragm

Incorrect Media Corrosion Compatibility Perforates and Leaks the Diaphragm

E45-010 · Sensor Selection and Range · Stainless steel pressure sensor 316L diaphragm · ★★★

Problem Description

A 316L diaphragm was used to measure a pH=13 strong alkali; after 3 months pitting perforated it and it leaked, the signal was interrupted and the media overflowed

Root Cause

[Mechanism] 316L pits in a pH13 strong-alkali + chloride environment, perforating at a rate of about 0.3 mm/month.
[Calculation] The diaphragm is 0.5 mm thick; it was eaten through in 3 months, leaking the media, breaking the Wheatstone bridge and losing the signal.
[Design Omission] The corrosiveness of the media was not checked and Hastelloy or PTFE lining was not selected; the material compatibility was wrong.

Corrective Solution

① Material matching: media pH13 + chloride → change the diaphragm to Hastelloy C276 or a PTFE lining (originally 316L); it resists strong alkali and is not eaten through (originally 0.3 mm/month, perforated in 3 months)
② Passivation confirmation: passivate the wetted parts and confirm corrosion resistance → defects in the passive film accelerate pitting; this keeps the diaphragm intact
③ Isolating pressure transmission: add a sealing diaphragm on the media side with silicone oil for pressure transmission → the sensor does not directly touch the corrosive media, extending service life
④ Corrosion-resistance grading: select the corrosion-resistance grade by media pH and chloride concentration → mismatches always corrode; select the material for the specific conditions
⑤ Periodic inspection: check the diaphragm appearance and insulation monthly → pitting progresses gradually; this enables early replacement
⑥ Leak detection: chamber humidity/pressure alarm → perforation interrupts the signal; this gives a timely alarm
⑦ Coupon test: run a corrosion coupon test to verify a service life ≥2 years → rated values are not guaranteed; confirm by actual measurement
⑧ Lock in material selection: write the media-corrosion cross-reference into the material selection table as a mandatory item → eliminate material-mismatch perforation at the source

Checklist

Reference

GB/T 13384 Packaging of mechanical and electrical products

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »