E45-100 · Signal Interference and EMC · Industrial Camera Trigger Line · ★★
When the switching supply next to the camera runs, triggers are dropped (3-5 out of every 100 frames)
[Mechanism] The switching supply's high-frequency EMI radiates and couples through the trigger line, producing false triggers and dropped frames.
[Calculation] With switching supply f=200kHz and harmonics up to tens of MHz, the field strength E≈-50dBm exceeds the trigger-line immunity, and false triggers cause dropped frames.
[Design Omission] The trigger line was not shielded, the supply was not filtered and not kept away.
① Shielded twisted pair: change the trigger line to shielded twisted pair with a 360° termination → suppresses radiation
② Supply filtering: add a π filter to the switching-supply output → reduces EMI at the source
③ Separation: keep the trigger line at least 200mm from the switching supply → reduces field strength
④ Differential triggering: switch to a differential trigger signal → better immunity
⑤ Ferrite bead: fit a ferrite core on the trigger line → absorbs high frequency
⑥ Filtering: add a low-pass filter at the trigger end → filters the spike
⑦ Verify by measurement: frame-drop rate with the supply at full load (≤0.1%) → confirmed
⑧ Institutionalize: write trigger-line EMC into the standard → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test