E45-430 · Vibration and Mechanical Stress · Load Cell · ★★

Problem Description

Vibration causes micro-motion between the load cell's elastic body and its support, so the zero point drifts slowly and the no-load reading is not zero

Root Cause

[Mechanism] Continuous vibration causes micro-slip between the elastic body and the support; the changed preload shifts the zero reference.
[Calculation] Vibration causes 0.02 mm micro-slip of the support; the changed elastic-body prestress drifts the zero point by 0.3%FS.
[Design Deficiency] No vibration-resistant mounting and no zero locking were provided.

Corrective Solution

① Vibration-resistant mounting: add isolation mounts to cut transmission → suppress micro-motion
② Zero lock: a mechanical stop limits micro-motion → stabilize the reference
③ Rigid connection: rigidly couple the elastic body to the base → eliminate slip
④ Periodic zeroing: re-zero at no load on schedule → correct drift
⑤ Creep compensation: the algorithm compensates creep drift → correct readings
⑥ Zero-drift monitoring: monitor the no-load zero and alarm → early detection
⑦ Drift verification: measure zero drift on a shaker table → data confirmation
⑧ Selection standardization: write vibration-resistant mounting into the spec → control at the source

Checklist

Reference

GB/T 7551-2008 Load cells