E45-429 · Vibration and Mechanical Stress · Vibration Sensor · ★★★
The natural frequency of the measured structure coincides with the excitation frequency and resonance occurs; the sensor reads amplitudes far above the true value, so the measurement fails
[Mechanism] Structural resonance sharply amplifies local amplitude; the sensor mounting point happens to lie outside the mode nodes, so readings are distorted.
[Calculation] The structure's natural frequency coincides with the rotational excitation frequency; amplitude is amplified 8 times and saturates the sensor beyond its range.
[Design Deficiency] No structural modal analysis was done to avoid the resonant speed.
① Modal analysis: model structural modes to avoid resonant speeds → pre-empt
② Speed avoidance: keep operating speed away from critical speeds → avoid resonance
③ Multi-point placement: cross-check multiple measurement points to avoid nodes → ensure accuracy
④ Damping: add damping structures to lower the Q factor → cut peaks
⑤ Constraint stiffening: add constraints to raise the natural frequency → shift away from resonance
⑥ Amplitude monitoring: monitor for sudden amplitude jumps and alarm → early detection
⑦ Resonance verification: sweep the frequency and check the amplitude peak → data confirmation
⑧ Selection standardization: write critical speeds into the operating spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test