E45-428 · Vibration and Mechanical Stress · Encoder · ★★
The encoder cable in the drag chain bends repeatedly under long-term vibration; conductor fatigue breaks the wire and position feedback is lost
[Mechanism] Repeated bending forms fatigue cracks in the copper conductors that gradually propagate to fracture; the shield and the core wires break one after the other.
[Calculation] After 100,000 drag-chain bending cycles, the conductor cross-section has lost 30%; the signal makes and breaks, dropping pulses.
[Design Deficiency] No high-flex cable intended for drag chains was used, and the bend radius was insufficient.
① High-flex cable: choose high-flex cable made for drag chains → resist bending
② Bend allowance: bend radius ≥ 10 times the cable diameter → reduce fatigue
③ Secure and uncoil: layer-secure cables inside the drag chain to prevent twisting → avoid tangling
④ Twist-resistant shield: use a twist-resistant shield construction → protect the shield
⑤ Slack layout: leave slack in the cable → reduce tensile stress
⑥ Break monitoring: monitor pulse loss and alarm → early detection
⑦ Fatigue verification: run a bending life test → data confirmation
⑧ Selection standardization: write drag-chain cable into the wiring spec → control at the source
GB/T 5013.1-2008 Rubber insulated cables of rated voltages 450-750 V