Knowledge Base › Electrical Sensor Error Case › Vibration-Induced Tightening Torque Decay

Vibration-Induced Tightening Torque Decay

E45-453 · Vibration and Mechanical Stress · Displacement Sensor · ★★

Problem Description

Vibration decays the preload of the sensor mounting bolts; the mounting loosens and the measurement becomes inaccurate

Root Cause

[Mechanism] Vibration makes the thread pair slip relative to each other and relaxes the preload; the clamping force drops and the mounting datum micro-moves.
[Calculation] Vibration reduces the M6 bolt preload by 30% per month; the mounting datum shifts and the measurement deviates.
[Design Deficiency] Neither the torque method nor anti-loosening was used.

Corrective Solution

① Torque method: tighten to spec → maintain preload
② Anti-loosening treatment: threadlocker or a locking washer → prevent loosening
③ Periodic re-tightening: check the torque on patrol → early correction
④ Mechanical locking: cotter pins or lock plates → positive locking
⑤ Loosening monitoring: alarm on mounting displacement → early detection
⑥ Preload check: verify the clamping force → ensure accuracy
⑦ Decay verification: confirm by measuring torque decay under vibration → data confirmation
⑧ Selection standardization: write torque and anti-loosening into the assembly spec → control at the source

Checklist

Reference

GB/T 50231-2009 General code for construction and acceptance of mechanical equipment installation engineering