E45-447 · Vibration and Mechanical Stress · Encoder · ★★
Vibration makes the rotary encoder disk tremble slightly; glitch pulses appear in the position feedback and cause errors
[Mechanism] Vibration makes the disk micro-move relative to the shaft; the instantaneous position jitter as the graduations sweep past the optical eye produces counting glitches.
[Calculation] A 0.01° disk jitter from vibration produces glitches in the position pulses, giving an error of ± several pulses.
[Design Deficiency] The encoder had no vibration isolation and the shaft system lacked rigidity.
① Rigid coupling: use a high-rigidity coupling → stabilize coaxiality
② Isolated mounting: add an isolation mount to the encoder → reduce chatter
③ Vibration-resistant selection: choose a vibration-resistant encoder → improve stability
④ Filtering: apply a moving-average filter to the signal → suppress glitches
⑤ Bearing reinforcement: raise the stiffness of the shaft bearings → reduce chatter
⑥ Error monitoring: alarm on position glitches → early detection
⑦ Chatter verification: confirm by measuring position error on a shaker table → data confirmation
⑧ Selection standardization: write vibration-resistant mounting into the spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test