E45-200 · Grounding and Shielding · High-Frequency Coaxial Signal Cable · ★★
The high-frequency (100MHz) coaxial signal exceeded the radiation limit and showed large reflections; on inspection the connector shield had not been crimped securely
[Mechanism] The coaxial shield must be connected 360° with low resistance to the connector shell to keep the characteristic impedance continuous; a loose termination or a few spot connections leaves the shield discontinuous, and the impedance step produces a reflection Γ while the current on the inner surface of the outer conductor leaks out and radiates.
[Calculation] A poor termination steps the characteristic impedance from 50Ω to 70Ω, giving a reflection Γ=(70-50)/(70+50)=0.17 and a return loss ≈15dB, out of spec; the discontinuous shield raises radiation by 20dB.
[Design Omission] The connector shield was hand-soldered rather than crimped with the proper tool, so the 360° connection was discontinuous.
① 360° crimp: use a coaxial crimp tool to join the shield all round to the plug shell → continuous impedance
② Proper connector: use an EMC coaxial connector (e.g. shielded N/SMA) → low impedance
③ Torque: tighten the connector nut to spec → firm contact
④ Impedance test: measure characteristic impedance 50Ω±2 → continuity confirmed
⑤ Return-loss test: measure return loss >20dB with a vector network analyser → confirmed
⑥ Radiation test: measure radiation margin >6dB → no leakage confirmed
⑦ Termination check: open it up and verify the shield has no looseness or broken strands → confirmed
⑧ Write the termination process into the high-frequency assembly specification → control at the source
GB/T 11313.1-2013 Radio-frequency connectors