E45-088 · Signal Interference and EMC · Servo Encoder EnDat · ★★
During servo operation the encoder reports CRC errors once or twice every 10 minutes, and the axis occasionally stops
[Mechanism] High-frequency common-mode interference couples along the encoder cable and corrupts the EnDat digital frame, so the CRC check fails and triggers an alarm.
[Calculation] At interference frequencies of 10~100MHz, without a ferrite bead the common-mode current induces noise Vn>0.3V on the line, exceeding the logic tolerance and causing CRC errors.
[Design Omission] The encoder cable had no ferrite bead, was not shielded twisted pair, and was not differential.
① Fit ferrite beads: put ferrite beads on both ends of the encoder cable (impedance ≥100Ω@100MHz) → absorbs common mode and drops CRC errors to zero
② Shielding and twisted pair: switch to shielded twisted pair with 360° termination → suppresses coupling
③ Differential transmission: use differential long-line signaling for EnDat → CMRR≥80dB
④ Keep away from the source: route the cable ≥200mm from VFDs and relays → reduces field strength
⑤ Termination matching: add a matching resistor → suppresses ringing
⑥ Filtering: add a TVS and low-pass filter at the signal end → clips spikes
⑦ Verification by test: 24h of continuous operation with no CRC error → confirm
⑧ Institutionalize: write the ferrite beads and shielding into the assembly card → gatekeeping
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test