E45-087 · Signal Interference and EMC · Ultrasonic Flowmeter · ★★
When the VFD is set to a certain frequency the ultrasonic flowmeter reading plunges 50% and jumps
[Mechanism] The VFD switching-carrier frequency falls within the mechanical/electrical resonance band of the ultrasonic transducer, and the strong acoustic and electromagnetic interference drowns out the echo, making the measurement inaccurate.
[Calculation] The VFD carrier f_c=25kHz coincides exactly with the transducer resonance f0=25kHz; the interference amplitude rises, the signal-to-noise ratio collapses, and the reading drops 50%.
[Design Omission] The carrier frequency was not offset, and the ultrasonic cable was not shielded or filtered.
① Offset the frequency: move the VFD carrier out of the resonance band (±5kHz) → avoids resonance and restores the reading
② Shielding and twisted pair: change the ultrasonic cable to shielded twisted pair → suppresses electromagnetic coupling
③ Band-pass filtering: add a band-pass filter at the signal end (centered at f0) → rejects the carrier interference
④ Isolation: add signal isolation → breaks the common-mode path
⑤ Keep away: place the sensor ≥1m from the VFD → reduces field strength
⑥ Power filtering: add π-filtering to the ultrasonic supply → stabilizes the supply
⑦ Verification by test: reading across the VFD's full frequency range (fluctuation ≤1%) → confirm
⑧ Institutionalize: write the carrier-avoidance rule into the commissioning card → gatekeeping
GB/T 17626.6-2017 Immunity to conducted disturbances induced by radio-frequency fields