E45-086 · Signal Interference and EMC · Encoder Long-Line SSI · ★★
Ringing on a 15m SSI signal causes a bit error rate of 3‰ and occasional position jumps
[Mechanism] Long-line distributed capacitance and an unmatched termination impedance produce reflected ringing; the edge overshoot misleads the sampling and causes misjudgment.
[Calculation] With a 15m line, distributed capacitance C≈60pF/m, total C≈900pF, characteristic impedance Z0≈100Ω, and no termination, the reflection coefficient Γ≈1 produces ringing overshoot and bit errors.
[Design Omission] There was no line termination, the cable was too long, and twisted pair was not used.
① Terminate the line: add a 100Ω matching resistor at the SSI end → eliminates reflected ringing
② Shorten the line: keep the length ≤10m or add a repeater → reduces distributed capacitance
③ Twisted-pair shielding: switch to shielded twisted pair → suppresses crosstalk
④ Lower the rate: reduce the clock frequency to match the line length → stable edges
⑤ Differential transmission: switch to RS485 differential → noise immunity
⑥ Ferrite beads: fit beads at both ends → absorbs high-frequency ringing
⑦ Verification by test: bit error rate test (≤1e-6) → confirm
⑧ Institutionalize: write the matching resistor into the wiring diagram → gatekeeping
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test