E45-332 · Environmental Protection and Temperature/Humidity · Vibration Sensor · ★★
Strong vibration loosens the enclosure's sealing screws; the protection fails, rainwater seeps in, and intermittent short circuits occur
[Mechanism] Sustained vibration gradually relaxes the preload of the sealing screws; gaps open at the sealing faces, rainwater seeps along them into the cavity, forms a leakage path, and causes intermittent short circuits.
[Calculation] A vibration acceleration of 5g decays the M4 screw preload by about 10% every ten thousand cycles; within a few weeks it loosens to the point of seal failure. After water ingress the insulation drops to the MΩ range.
[Design Omission] The sealing fasteners were given no anti-loosening provision, and the effect of vibration on the seal was not assessed.
① Anti-loosening fastening: add spring washers and threadlocker to the sealing screws → resist vibration loosening
② Upgraded sealing: replace the flat washer with a one-piece compressed seal ring → stays in contact under vibration
③ Potting: pot the terminal cavity with silicone → no leakage even with minor seepage
④ Vibration-damped mounting: add a damping pad under the sensor base → reduce the vibration reaching the seal
⑤ Waterproof cable exit: cable gland plus drip loop → block the seepage path
⑥ Periodic inspection: check screw torque and insulation monthly → catch loosening early
⑦ Vibration verification: run combined vibration and rain tests to confirm no seepage → data confirmation
⑧ Selection standardization: write the anti-loosening requirement for vibration duty into the installation card → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration (sinusoidal) test