E45-113 · Signal Interference and EMC · Shielded Signal Cable Terminal · ★★
After the shield is crimped through a terminal block, the noise is 8dB higher than with a direct ground connection
[Mechanism] Breaking the shield at a terminal block and crimping it there introduces contact resistance and a break point, making the shield discontinuous, raising the transfer impedance and increasing picked-up noise.
[Calculation] With a terminal contact resistance Rc≈50mΩ and the shield discontinuous at high frequency, the transfer impedance Zt rises and the coupling adds 8dB of noise.
[Design Omission] The shield was not terminated 360°, was routed through a terminal block, and was not continuous.
① 360° termination: bond the shield to the housing with a metal connector ring → continuous shield, noise down 8dB
② Direct connection: do not route the shield through a terminal block → keep it continuous
③ Equipotential bonding: equipotential between the two cabinets (≤0.1Ω) → no circulating current
④ High-density shield: change to a braid coverage ≥85% → stronger shielding
⑤ Isolation: isolate the signal → cuts common mode
⑥ Rework: remove the terminal-block routing and use a ring termination → shield restored
⑦ Verify by measurement: check the noise on the spectrum (down 8dB) → confirmed
⑧ Institutionalize: write the shield-termination method into the standard → gate at the source
GB/T 17626.6-2017 Immunity to conducted disturbances induced by radio-frequency fields