Knowledge Base › Electrical Sensor Error Case › Cable Temperature Rating Too Low Near a Heat Source Melts the Jacket and Shorts

Cable Temperature Rating Too Low Near a Heat Source Melts the Jacket and Shorts

E45-039 · Cables and Drag Chains · Temperature Rating of a Drag Chain Beside an Injection Molding Machine · ★★

Problem Description

The PVC cable in the drag chain (rated 70℃) is routed close to an 80℃ oil line; the jacket softens and melts, 2 cores stick together and short, and temperature control fails

Root Cause

[Mechanism] A PVC jacket's long-term upper service temperature is 70℃; an 80℃ ambient exceeds the rating, so the jacket thermally ages, softens and melts, and the insulation fails and shorts.
[Calculation] An 80℃ ambient is 10℃ above the 70℃ rating; halving the thermal life per 10℃ reduces it from 10 years to about 5 years, and softening causes a short.
[Design Omission] The temperature rating was not selected according to the ambient temperature, and the heat source was not isolated.

Corrective Solution

① Raise the rating: switch to a silicone-rubber or XLPE cable rated ≥105℃ → does not soften at 80℃ ambient
② Isolate the source: keep the cable ≥100mm from the 80℃ oil line or add a heat shield → lowers its own temperature
③ Institutionalize the rating: make the ambient temperature a mandatory item in the selection table → gatekeeping at the source
④ Temperature test: measure the cable surface temperature after installation (≤ rating−10℃) → confirm by measurement
⑤ Insulation: wrap the heat-source side with an aluminum-foil heat sleeve → reflects heat and lowers temperature
⑥ Inspection: check monthly whether the jacket has softened → catch progressive aging and replace early
⑦ Routing: route the cable away from high-temperature zones → less heat exposure
⑧ Maintenance: add to the monthly check list → inspect periodically

Checklist

Reference

GB/T 5013.1-2008 Rubber-insulated cables