E45-120 · Signal Interference and EMC · Precision Weighing · ★★
A nearby LC oscillator tank raises the precision-measurement noise by ±0.1%FS
[Mechanism] The radiated magnetic field of the LC oscillator tank couples into the high-impedance precision-measurement signal and introduces noise.
[Calculation] With oscillator f=1MHz and a high Q, the magnetic field B induces a voltage e in the measurement loop, raising the noise by ±0.1%FS.
[Design Omission] The measurement cable was not shielded, not kept away and not filtered.
① Shielded twisted pair: run the measurement cable as shielded twisted pair → suppresses coupling and lowers noise
② Move away from the oscillator: keep at least 0.5m from the oscillator tank → reduces field strength
③ Ferrite bead: fit a ferrite core on the leads → absorbs high frequency
④ Low-pass filtering: add a low-pass filter → filters out the noise
⑤ Isolation: isolate the signal → cuts common mode
⑥ Shield the oscillator: enclose the oscillator tank in a metal shield can → reduces radiation at the source
⑦ Verify by measurement: noise under oscillator conditions (≤0.02%FS) → confirmed
⑧ Institutionalize: write precision-measurement EMC into the standard → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test