E45-090 · Signal Interference and EMC · Cabinet-Level EMC · ★★
The equipment's EMI test exceeds the limit by 12dB at 30MHz, and radiated emission fails the standard
[Mechanism] The cabinet has no EMC filtering, so noise from the switching supply and the relays radiates through the cables and pushes emission over the limit at 30MHz.
[Calculation] Without filtering the 30MHz radiated field strength E≈40dBμV/m exceeds the 30dBμV/m limit by 12dB; the cables act as transmitting antennas.
[Design Omission] No power-line filter was fitted, the cables were not shielded, and the cabinet itself was not shielded.
① Power filtering: add an EMI power-line filter at the incoming line (insertion loss ≥30dB at 30MHz) → emission drops 12dB to meet the limit
② Cable shielding: use shielded twisted pair for all outgoing cables with 360° termination → suppresses radiation
③ Cabinet shielding: fit conductive gaskets to the seams of the continuously conductive cabinet → shielding ≥40dB
④ Board-level filtering: add π-filtering to the supply of every board → reduces noise at the source
⑤ Filter grounding: bond the filter case directly to the cabinet with low resistance → effective discharge
⑥ Relay treatment: add RC snubbers and a shielded box to the relays → arc suppression
⑦ Verification by test: re-test EMI (30MHz ≤ limit) → confirm compliance
⑧ Institutionalize: write the EMC filtering design into the specification → gatekeeping
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test