E45-251 · Wiring and Terminals · Long-Term-Service Terminal · ★
After three years in service the spring terminal's clamping force dropped and the contact opened intermittently
[Mechanism] Under long-term heat and vibration the spring material of the terminal stress-relaxes, so the clamping force decays; the wire frets under the reduced pressure and the contact resistance grows until the connection momentarily opens.
[Calculation] Spring relaxation lowers the clamping force from an initial 8N to below 3N and raises the contact resistance from 0.02Ω to 0.5Ω; the signal loses frames.
[Design Omission] No relaxation-resistant spring was selected, no periodic re-tightening, and no life evaluation.
① Relaxation-resistant spring: choose a relaxation-resistant spring terminal → durable
② Re-tightening: re-compress the wire periodically → restore the force
③ Life check: replace at end of life → no aging
④ Contact measurement: check the resistance holds <0.05Ω → confirmation
⑤ Inspection: check periodically for no loosening → early prevention
⑥ Redundant fixing: terminate critical wires at both ends → no loss
⑦ Frame-loss alarm: alarm on dropped frames → early warning
⑧ Write the spring life into maintenance → control at the source
GB/T 14048.7-2016 Low-voltage switchgear and controlgear — Ancillary equipment — Terminal blocks for copper conductors