E45-338 · Environmental Protection and Temperature/Humidity · Humidity Sensor · ★★
In a tropical high-humidity environment mould grows on the circuit board; the mould filaments form leakage paths, degrading insulation and drifting the signal
[Mechanism] Under high temperature and humidity, mould grows on organic residues on the circuit board; the moisture-absorbing conductive filaments form micro leakage paths that degrade insulation and drift the signal.
[Calculation] At a sustained 28℃ and 85% RH, mould forms colonies within weeks; insulation can drop to a few MΩ, and μA-level leakage interferes with weak signals.
[Design Omission] No anti-mould conformal coating was applied and there was no humidity control.
① Conformal coating: spray anti-mould conformal coating on the circuit board → inhibit filament attachment
② Humidity control: add dehumidification or heating in the cabinet to keep humidity <60% → suppress mould
③ Clean assembly: clean before assembly to remove organic residues → cut off mould nutrients
④ Potting against moisture: pot critical areas → isolate moisture
⑤ Desiccant: place desiccant in the cavity → control local humidity
⑥ Insulation monitoring: alarm when <10MΩ → detect degradation early
⑦ Hot-humid verification: run a hot-humid plus mould test to confirm → data confirmation
⑧ Selection standardization: write hot-humid-environment conformal-coating requirements into the spec → control at the source
GB/T 2423.16-2022 Environmental testing for electric and electronic products - Mould growth test