E45-164 · Power Supply · Fan-Cooled Supply Module · ★★
The heatsink fan of the supply module seizes, and the module shuts down from overtemperature periodically
[Mechanism] The fan bearing seizes and stops; heat builds up in the module until the overtemperature protection shuts it down, and after it cools the cycle repeats.
[Calculation] With the fan stopped the temperature rise ΔT doubles and the case temperature exceeds 70℃ → shutdown; replacing the fan restores it, and a fan-blockage alarm gives warning.
[Design Omission] The fan had no stall alarm, was not maintained periodically, and there was no thermal-control redundancy.
① Fan blockage alarm: detect fan stall and alarm → replace early
② Periodic maintenance: clean dust and lubricate bearings every six months → prevents seizing
③ Redundant fans: two fans, one on standby → one stopping still leaves cooling
④ Thermal derating: derate automatically at high temperature → no overheating
⑤ Temperature monitoring: alarm when case temperature >60℃ → early intervention
⑥ Fan-stop test: with the fan stopped the module must not shut down → confirms redundancy
⑦ Maintenance-free fans: choose long-life bearings → less maintenance
⑧ Write fan maintenance into the specification → gate at the source
GB/T 7260.3-2003