E45-215 · Grounding and Shielding · Coaxial Measurement Cable · ★
Bending the coaxial cable shifted its shield off centre, reducing the common-mode rejection of the differential signal and raising the noise
[Mechanism] A coaxial structure relies on the shield being strictly coaxial with the inner conductor so that the characteristic impedance stays constant along its length; bending breaks that coaxiality, the distributed capacitance C becomes uneven, the impedance step reflects and destroys symmetry, and more common-mode noise converts to differential mode.
[Calculation] The loss of coaxiality changes the local C by 5% and the impedance Z=√(L/C) by 2.5%, giving a reflection Γ≈0.025, and the capacitance imbalance drops the CMRR by 10dB.
[Design Omission] The cable was bent at a small radius, destroying its coaxial geometry.
① Large bend radius: keep the cable bend radius >10 times the outer diameter → preserve coaxiality
② Flexible coax: use flexible coaxial cable (stranded inner conductor) → tolerates bending without deformation
③ Secured routing: fix the cable with ties so it is not bent → stable geometry
④ Impedance test: measure characteristic impedance 50Ω±2 → coaxiality confirmed
⑤ Return-loss test: return loss >20dB → no impedance step confirmed
⑥ CMRR test: measure CMRR with no drop → symmetry confirmed
⑦ Bend check: visually inspect for sharp bends → confirmed
⑧ Write the bend radius into cable installation → control at the source
GB/T 11313.1-2013 Radio-frequency connectors