E45-150 · Power Supply · Paralleled Power Modules · ★★
Two supplies in parallel: one runs fully loaded while the other idles, and the loaded one goes into over-temperature protection
[Mechanism] A tiny difference in output voltage between paralleled modules concentrates the current in the higher-voltage module while the lower-voltage one is back-fed or idles; the unequal sharing overloads a single unit.
[Calculation] A 0.1V offset with 0.02Ω internal resistance gives a 5A sharing error that pushes one unit past its rating; a current-sharing module can hold the deviation <5%.
[Design Omission] Supplies without a current-sharing function were paralleled directly, with no current balancing.
① Current-sharing supply: choose supplies with a share bus → current deviation <5%
② Output trim: trim the two modules to match (difference <0.05V) → even sharing
③ Redundancy derating: total capacity ≥2× the load → no single unit overloaded
④ Current monitoring: display the current of each module → imbalance shows up early
⑤ Hot swap: a failed module can be replaced online → no supply interruption
⑥ Sharing measurement: the current ratio of the two modules is (1±0.05) → confirmed
⑦ Independent filtering: filter each output → no mutual interference
⑧ Write the current-sharing design into the power drawing → gate at the source
GB/T 7260.3-2003