E45-151 · Power Supply · Switching Power Supply Equipment · ★★
Touching the equipment enclosure gives a tingling sensation (leakage current about 0.8mA), which does not meet safety standards
[Mechanism] The Y capacitor between the primary and secondary of a switching supply suppresses common-mode noise, but its leakage current flows through the enclosure to ground; when it is too large, touching the enclosure tingles.
[Calculation] With a 2.2nF Y capacitor at 220V/50Hz the leakage current I=2πfCU ≈ 0.8mA exceeds the 0.25mA safety limit (Class I) → tingling; reducing the Y capacitor or providing reliable grounding solves it.
[Design Omission] The Y capacitor was oversized, the protective ground was unreliable, and the leakage current was not measured.
① Reduce the Y capacitor: from 2.2nF down to 1nF → leakage current <0.4mA, within limits
② Reliable grounding: protective-ground resistance ≤0.1Ω → the leakage current flows to ground and no tingling occurs
③ Low-leakage supply: choose a medical / Class B supply with leakage current ≤0.25mA → compliant
④ Double insulation: a Class II design does not rely on grounding → no tingling
⑤ Leakage measurement: measure the leakage current with the ground resistance in place, ≤0.25mA → confirmed
⑥ Safety review: meets the GB/T 9254 limits → compliant
⑦ Shield grounding: bond the enclosure to protective earth → safe
⑧ Write the Y-capacitor selection into the safety design → gate at the source
GB/T 9254-2008 Radio disturbance of information technology equipment