E45-460 · Vibration and Mechanical Stress · Pressure Sensor · ★★★
A single hydraulic impact exceeds the diaphragm rating; the diaphragm is permanently dented, making the zero and linearity out of tolerance
[Mechanism] Impact drives the diaphragm stress beyond yield, causing permanent denting; the geometric shift makes the output deviate irreversibly.
[Calculation] An impact of twice the range dents the diaphragm by 0.05mm, shifting the zero by 1% FS out of tolerance.
[Design Deficiency] No overpressure protection or flow restriction was provided.
① Overpressure protection: add a pressure-limiting valve to limit the impact → protect the diaphragm
② Buffer damping: add a damping orifice to absorb the impact → reduce the peak
③ Range margin: keep a 2x range margin → avoid overrange
④ Mechanical stop: add a stop behind the diaphragm → limit displacement
⑤ Zero-reset check: re-zero after impact and measure the residual → early correction
⑥ Damage monitoring: monitor the zero residual → early detection
⑦ Dent verification: confirm by measuring the residual after an overload impact → data confirmation
⑧ Selection standardization: write overpressure protection into the design items → control at the source
GB/T 2423.5-2019 Environmental testing for electric and electronic products - Shock test