E45-079 · Signal Interference and EMC · Load Cell · ★★
After an adjacent 200A busbar is energized the weighing zero drifts by +0.3kg (it was ≤0.02kg) and returns to zero when the busbar is switched off
[Mechanism] The high-current busbar produces a magnetic field that induces an EMF in the two-wire weighing signal loop; superimposed, it shifts the zero point.
[Calculation] With I=200A, distance r=0.3m, B=μ0I/2πr≈1.33e-4T and loop area A=2cm², the induced e≈8.4μV; through low-gain amplification and imbalance it produces +0.3kg.
[Design Omission] The millivolt cable was not twisted, not shielded, not kept away from the high current, and not isolated.
① Twisted-pair shielding: change the weighing cable to shielded twisted pair with the shield grounded at one end → loop area approaches zero and induction drops 90%
② Keep away from the busbar: keep the sensor cable ≥0.5m from the 200A busbar → lower B
③ Isolated amplification: add an isolated instrumentation amplifier at the front end (isolation ≥1kV) → cuts common mode
④ Symmetric twin conductors: use matched symmetric conductor pairs → differential-mode rejection
⑤ Low-pass filtering: add a low-pass filter (cutoff 10Hz) → suppresses mains frequency
⑥ Zero-drift compensation: auto-zero the drift in software when power is cut → real-time correction
⑦ Verification by test: zero point with the busbar at full load (≤0.02kg) → confirm
⑧ Institutionalize: write the millivolt cable routing into the card → gatekeeping at the source
GB/T 17626.6-2017 Immunity to conducted disturbances induced by radio-frequency fields