E45-078 · Signal Interference and EMC · Pressure Sensor · ★★
The reading jitters at high frequency within ±0.5% of full scale (it was ≤±0.05%), and an FFT shows a 100kHz spike
[Mechanism] The 100kHz ripple of the switching supply is conducted along the supply line and coupled into the sensor bridge voltage, so the output carries noise at the same frequency.
[Calculation] With ripple Vpp≈50mV and power-supply rejection ratio PSRR=40dB, the output noise is ≈50mV/100=500μV, corresponding to ±0.5%FS jitter.
[Design Omission] No low-ripple linear regulator was used, no π-filter was added, and the supply and signal shared a ground.
① Linear regulation: power the sensor from an LDO (ripple ≤10μV) → jitter drops to ±0.05%
② π-filtering: add an LC π-filter at the supply end (10μH+10μF×2) → the ripple attenuates by 40dB
③ Independent supply: separate the sensor supply from the digital circuits → cuts conduction
④ High PSRR: choose a sensor with PSRR≥80dB → it suppresses ripple internally
⑤ Local decoupling: place 0.1μF+10μF next to each device → local stability
⑥ Star grounding: ground the analog ground at a single point → reduces common-ground noise
⑦ Verification by test: the 100kHz spike disappears in the FFT (jitter ≤±0.05%) → confirm
⑧ Institutionalize: write the supply filtering into the power diagram → gatekeeping at the source
GB/T 17626.6-2017 Immunity to conducted disturbances induced by radio-frequency fields