E45-249 · Wiring and Terminals · Displacement-Sensor Plug · ★
Improper plugging bent the pins; once inserted the contact made and broke, and the displacement reading jumped
[Mechanism] The plug was forced in without being aligned, so the pins bent and deformed; the contact area with the socket shrank or was lost altogether, and the contact made and broke under vibration.
[Calculation] A 0.3mm pin misalignment reduces the contact area by 70% and raises the contact resistance from 0.01Ω to 0.3Ω; the signal jitter exceeds tolerance.
[Design Omission] No alignment guidance, no specified insertion force, and no keying on the connector.
① Keying: align the guide before insertion → no bending
② Insertion force: insert and remove with the specified force → no bending
③ Pin check: check the pins are straight before insertion → confirmation
④ Contact measurement: measure the contact resistance <0.05Ω → secure
⑤ Keyed connector: choose a connector with keying → no mistake
⑥ Gentle insertion: do not force the plug → protect the pins
⑦ Intermittent-contact alarm: alarm on make-and-break → early warning
⑧ Write the insertion procedure into maintenance → control at the source
GB/T 5095.2-1997 Electromechanical switches for use in electronic equipment — Part 2: Test methods