E45-134 · Power Supply · Wireless Temperature/Vibration Sensor · ★
A wireless temperature/vibration sensor loses data every day from 03:00 to 05:00; the battery falls from 3.6V to 3.0V (3.3V cutoff) and the sensor goes to sleep
[Mechanism] A lithium-thionyl-chloride battery's discharge curve varies with temperature and load: in the cold its internal resistance rises and the usable capacity falls; once the terminal voltage drops below the module's undervoltage lockout (UVLO) threshold, the radio module shuts down and stops transmitting.
[Calculation] The battery is rated 3.6V/19Ah, but at −20℃ the capacity is only 60% ≈ 11.4Ah; an 80mA transmit peak current gives an internal-resistance drop ΔU=I×r, and with aged resistance up to 5Ω the peak drop is 0.4V, taking the voltage to 3.2V < the 3.3V UVLO → shutdown.
[Design Omission] No battery capacity and life calculation was done: the selection was based on room-temperature capacity with no allowance for cold or aging, there was no low-battery warning, and the transmit interval did not adapt to the state of charge.
① Capacity margin design: choose a capacity ≥2× the annual consumption (including cold and aging effects) → no dropout over the whole service life
② Cold-resistant battery: use Li-SOCl₂ with insulation or a low-temperature type (−40℃ capacity ≥80%) → no voltage collapse in the cold
③ Low-battery warning: report for replacement when the voltage <3.4V → intervene early, no data loss
④ Adaptive transmit interval: lengthen the interval at low charge to cut the peak → longer runtime
⑤ Supercapacitor buffer: parallel a supercapacitor to absorb the transmit peak → the terminal voltage does not fall through UVLO
⑥ Cold discharge-curve test: terminal voltage at −20℃ ≥3.4V → confirmed sufficient
⑦ Scheduled (quarterly) battery replacement: replace ahead of the capacity-decay curve → no supply interruption
⑧ Write the power budget into the wireless selection table → gate at the source
GB/T 28163-2011