E45-451 · Vibration and Mechanical Stress · Fiber-Optic Module · ★★
Vibration repeatedly micro-bends the optical fiber; fatigue fracture breaks it and interrupts the optical signal
[Mechanism] Repeated micro-bending subjects the fiber sidewall to alternating stress; a crack initiates and propagates until it breaks completely and the optical path is lost.
[Calculation] Vibration drives the fiber bending stress beyond the fatigue limit, and it breaks after 100,000 cycles, interrupting communication.
[Design Deficiency] The fiber was not fixed against bending and the radius was too small.
① Fixing against bending: secure the fiber reliably to avoid micro-bending → reduce stress
② Bend allowance: keep the bend radius ≥ 20× the diameter → prevent fracture
③ Protective tube: run the fiber through a tube for vibration protection → protect the fiber
④ Coil the excess: coil the surplus in large loops to avoid sharp bends → prevent fracture
⑤ Optical power monitoring: alarm on optical power → early detection
⑥ Break-point location: locate the break point → fast repair
⑦ Fatigue verification: confirm with a vibration bending test → data confirmation
⑧ Selection standardization: write fiber fixing into the construction spec → control at the source
GB/T 13993.1-2014 Optical fibre cables for communication - Part 1: General