E45-123 · Signal Interference and EMC · Inductive Displacement Sensor · ★★
When the high-frequency quenching machine runs, the displacement sensor jumps ±10μm (normally ≤1μm)
[Mechanism] The quenching machine's high-frequency (tens of kHz) strong field couples into the displacement-sensor coil and leads, shifting the resonance and causing the jumps.
[Calculation] With quenching frequency f≈30kHz and field strength B≈3mT, a voltage e is induced in the sensor cable and causes ±10μm jumps.
[Design Omission] The sensor was not shielded, not moved away, not filtered and not magnetically shielded.
① Magnetic shielding: fit the sensor with an iron tube / permalloy sleeve → attenuates the external magnetic field by 20dB
② Move away from the quencher: keep at least 2m from the machine → reduces B
③ Shielded twisted pair: run the leads as shielded twisted pair → suppresses coupling
④ Low-pass filtering: add a low-pass filter (10Hz cutoff) → filters the high frequency
⑤ Isolation: isolate the signal → cuts common mode
⑥ Avoid resonance: stay clear of the quenching frequency band → reduces resonance
⑦ Verify by measurement: readings under quenching conditions (jumps ≤1μm) → confirmed
⑧ Institutionalize: write keeping the displacement sensor away from the quencher into the standard → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test