E45-122 · Signal Interference and EMC · Resolver · ★★
The unshielded resolver leads push the angle-reading error to ±0.5° (normally ≤0.05°)
[Mechanism] The unshielded resolver excitation and sine/cosine leads pick up interference, producing an angle error in the resolver-to-digital conversion.
[Calculation] An interference of Vn≈50mV superimposed on the sine/cosine (amplitude 5V) gives an angle error of ±0.5°; after shielding it becomes negligible.
[Design Omission] The resolver cables were not shielded, not twisted and not kept away.
① Shielded twisted pair: change the resolver cable to shielded twisted pair with a 360° shield termination → suppresses pickup, error goes to zero
② Move away from the source: keep at least 200mm from the VFD/relay → reduces field strength
③ Ferrite bead: fit a ferrite core on the leads → absorbs high frequency
④ Low-pass filtering: add a low-pass filter → filters out the interference
⑤ Isolation: isolate the conversion circuit → cuts common mode
⑥ Single-end grounding: ground the shield at one point → avoids ground loops
⑦ Verify by measurement: error over the full rotation (≤0.05°) → confirmed
⑧ Institutionalize: write resolver-cable EMC into the standard → gate at the source
GB/T 17626.6-2017 Immunity to conducted disturbances induced by radio-frequency fields