E45-433 · Vibration and Mechanical Stress · Force Sensor · ★★
An overload shock subjected the force sensor's strain gauge backing to excessive stress; the backing cracked and the sensitivity was lost
[Mechanism] Overload drives the elastic body strain beyond the strain gauge's allowable value; the backing and grid lines crack under tension and open the bridge circuit.
[Calculation] Overload to 150% of rating drives the elastic body strain beyond 3000με, exceeding the strain gauge limit and causing cracking.
[Design Deficiency] No mechanical overload limit protection was provided.
① Mechanical stop: add a mechanical stop to limit overload → protect the strain gauge
② Overload selection: leave a 1.5x margin in the range → avoid overload
③ Cushioning: add a buffer structure to absorb the shock → reduce the peak
④ Redundant bridge: dual bridges as mutual backup → maintain availability
⑤ Overload monitoring: alarm when the load exceeds the rating → early detection
⑥ Periodic calibration: check for sensitivity decay → early correction
⑦ Overload verification: confirm by measuring cracking in an overload test → data confirmation
⑧ Selection standardization: write overload protection into the design items → control at the source
GB/T 7551-2008 Load cells