E45-434 · Vibration and Mechanical Stress · Communication Module · ★★
Vibration made the communication cable rub against an edge for a long time; the shielding braid wore through, the exposed conductor contacted ground and shorted, and communication was interrupted
[Mechanism] The cable frets against the fixed edge; once the shield wears through, the conductor contacts ground and forms a short circuit.
[Calculation] Vibration accumulates cable abrasion; after 3 months the shield is worn through, the conductor shorts to ground, and communication fails.
[Design Deficiency] No protective sleeve was added, and the fixing point had a sharp edge.
① Protective sleeve: sleeve the wear point with a corrugated tube or sheath → block wear
② Chamfering: round the edge at the fixing point to remove the sharp corner → prevent scuffing
③ Cable ties: secure the cable reliably to reduce micro-motion → reduce wear
④ Wear-resistant cable: choose a cable with a wear-resistant outer sheath → resist abrasion
⑤ Spacing: leave a gap between the cable and the edge → prevent contact
⑥ Insulation monitoring: alarm on the inter-line insulation → early detection
⑦ Wear verification: confirm with a vibration abrasion test → data confirmation
⑧ Selection standardization: write wear-point protection into the wiring spec → control at the source
GB/T 5013.1-2008 Rubber insulated cables of rated voltages 450-750 V