E45-343 · Environmental Protection and Temperature/Humidity · Flow Sensor · ★★
A high-pressure steam leak sprays onto the connector; hot pressurized water vapor enters it and corrodes and oxidizes the terminals
[Mechanism] Hot pressurized water vapor enters through the connector gaps; after condensing it reacts with and oxidizes the terminal metal, and the oxide film raises contact resistance and attenuates the signal.
[Calculation] A 0.4MPa/140℃ steam jet penetrates the IP65 seal; the condensate oxidizes the terminals within weeks and contact resistance rises to the Ω level.
[Design Omission] The connector's protection rating was insufficient and it could not withstand high-temperature steam.
① Steam-resistant protection: choose an IP68 connector with a 140℃-rated seal → resist steam ingress
② Guard: add a stainless-steel splash guard to the connector → block the jet
③ Pot the terminals: pot the terminals in silicone → isolate the water vapor
④ Gold-plated terminals: gold-plate the terminals → resist oxidation
⑤ Leads downward: route the cable downward with a drip loop → no water accumulation
⑥ Insulation monitoring: alarm when <10MΩ → early ingress warning
⑦ Steam verification: run a high-temperature steam spray test → data confirmation
⑧ Selection standardization: write steam-duty protection into the selection spec → control at the source
GB/T 4208-2017 Degrees of protection provided by enclosures (IP code)