E45-103 · Signal Interference and EMC · Grating Scale · ★★
While the servo runs, the grating scale reading jumps ±5μm (originally stable at ±0.5μm) and the position loop oscillates
[Mechanism] The servo drive's high-frequency PWM noise couples through the readhead cable and the mounting surface into the grating signal, making the count jump.
[Calculation] With PWM noise f≈16kHz and amplitude Vn≈0.2V exceeding the grating logic margin of 0.1V, the count jumps ±5μm.
[Design Omission] The readhead cable was not shielded, not kept away from the drive and not filtered.
① Shielded twisted pair: change the readhead cable to shielded twisted pair with a 360° termination → suppresses coupling
② Move away from the drive: keep the cable at least 200mm from the servo drive → reduces field strength
③ Ferrite bead: fit ferrite cores at both ends → absorbs high frequency
④ Low-pass filtering: add a low-pass filter → filters the residual PWM noise
⑤ Isolation: isolate the signal → cuts common mode
⑥ Grounding: ground the readhead housing at one point → avoids ground loops
⑦ Verify by measurement: readings with the servo at full speed (jumps ≤0.5μm) → confirmed
⑧ Institutionalize: write grating-cable EMC into the standard → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test