E45-472 · Vibration and Mechanical Stress · Encoder · ★★★
Vibration fatigues and fractures the encoder's flexible coupling; position feedback is lost and the equipment stops
[Mechanism] Under vibration and torsional oscillation, fatigue cracks in the coupling propagate until it fractures; the encoder loses connection and the position reference is lost.
[Calculation] The coupling stress exceeds the fatigue limit and it fractures after several months of operation, causing loss of position feedback.
[Design Deficiency] The coupling was not selected for torsional-vibration resistance.
① Torsional-vibration type: choose a torsional-vibration-resistant coupling → extend service life
② Alignment accuracy: improve shaft alignment → reduce stress
③ Damped support: add vibration isolation to the shaft system → stabilize the shaft
④ Redundant check: monitor the zero pulse → early detection
⑤ Regular inspection: check for cracks → early correction
⑥ Disconnection monitoring: alarm on position loss → early detection
⑦ Fracture verification: confirm with a vibration endurance test → data confirmation
⑧ Selection standardization: write the coupling selection into the spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test