E45-400 · Communication and Bus · Communication Module · ★★★
Occasional error frames from a CAN node are not handled; the error counter overflows and the node goes bus-off and offline
[Mechanism] A single node that keeps transmitting error frames pushes its transmit error counter past 255 into the bus-off state, paralyzing network-wide communication.
[Calculation] Sixteen consecutive errors push the error count past 255 and trigger bus-off; the node goes offline and loses all messages.
[Design Deficiency] No node self-recovery or error isolation was provided.
① Self-recovery: recover automatically after bus-off → stay online
② Error isolation: quickly take a bad node offline and isolate it → protect the whole network
③ Termination: 120 Ω terminators at both ends of the CAN bus → suppress reflection
④ Consistent baud: one baud rate across the network → prevent error frames
⑤ Load control: keep bus load <70% → fewer conflicts
⑥ Error monitoring: monitor the error counter and alarm → early detection
⑦ Bus-off verification: inject errors and test self-recovery → data confirmation
⑧ Selection standardization: write CAN fault tolerance into the network spec → control at the source
ISO 11898-1:2015 Road vehicles - Controller area network (CAN) - Part 1: Data link layer and physical signalling