Magnetic Level Gauge Installed Directly Below the Feed Jams the Float

E45-021 · Installation Position and Orientation · Magnetic Level Gauge on a Reactor · ★★

Problem Description

Installed 200mm directly below the feed pipe, the float is jammed by the jet impact; the flags stop turning and the level display freezes

Root Cause

[Mechanism] The feed jet creates strong turbulence and vortex-induced vibration at the float; the float deflects out of its guide clearance and jams.
[Calculation] Feed velocity v = 2m/s, turbulence intensity in the jet-impact zone >30%, float deflection > the 2mm guide clearance, so it jams.
[Design Omission] The feed zone was not avoided, no guide tube was provided, and no flow-field check was made.

Corrective Solution

① Away from the jet: move it at least 500mm from the feed inlet or mount it on the side (was 200mm directly below) → avoids the feed jet and keeps the float from deflecting and jamming
② Guide tube: add a float guide tube to hold deflection <1mm → turbulence pushes it off center; keep it centered
③ Tangential feed: change the feed inlet to tangential distribution to cut direct impingement → axial impact is strong; soften it
④ Heavier float: choose a heavier float for stability (the original was light) → a light float drifts easily; use a disturbance-resistant one
⑤ Connecting-pipe size: keep the connecting pipe at ≥ half the main diameter for flow → a thin pipe clogs; keep it flowing
⑥ Jam check: exercise the float monthly to check for jamming → sticking builds up gradually; correct it early
⑦ Fill test: run a fill test to watch the float follow → design often skips it; confirm by measurement
⑧ Make it stick: write the feed-avoidance requirement into the level-gauge installation drawing → eliminates jamming directly under the feed at the source

Checklist

Reference

HG/T 21584 Magnetic level gauges