Knowledge Base › Electrical Sensor Error Case › Response Time Mismatch Misses Impact Peaks

Response Time Mismatch Misses Impact Peaks

E45-005 · Sensor Selection and Range · Vibration accelerometer piezoelectric · ★★

Problem Description

Impact monitoring required a response ≤1 ms but a slow 10 ms sensor was selected; the 5 g impact peak was smoothed to 2 g, the fault went unreported and equipment damage spread

Root Cause

[Mechanism] The sensor's low natural frequency gives a 10 ms step response; a 2 ms impact pulse is smoothed by integration and only 40% of the peak is captured.
[Calculation] Losing the peak makes both RMS and peak read low, so the threshold judgment does not trigger an alarm.
[Design Omission] The sensor bandwidth was not checked for ≥5× the signal frequency and no high-frequency-response model was selected; the response is mismatched.

Corrective Solution

① Frequency-response matching: impact pulse width 2 ms → select an IEPE accelerometer with a natural frequency ≥5 kHz and response ≤0.2 ms to fully capture the 5 g peak (originally 10 ms captured only 40%)
② Signal chain bandwidth: signal-chain bandwidth ≥10 kHz (amplifier + acquisition) → avoid a second smoothing stage and keep the peak undistorted
③ Sampling rate: sampling rate ≥20 kHz (originally 1 kHz) → satisfy the sampling theorem with >2× the highest frequency and avoid aliasing
④ Peak hold: add a peak-hold circuit to latch the impact peak → transient peaks are easily missed; latching provides a value for judgment
⑤ Impact alarm: trip at a peak >3 g → without an alarm the fault spreads; this stops the machine in time to limit damage
⑥ Rigid mounting: bolt directly to reduce mechanical filtering → eliminate the extra damping and smoothing of soft mounting and preserve fidelity
⑦ Shock-table calibration: use a standard shock table to verify the response ≤0.2 ms → rated values are often inflated; confirm by actual measurement
⑧ Lock in selection: write the bandwidth ≥5× signal frequency into the vibration monitoring selection table → eliminate response mismatch and missed alarms at the source

Checklist

Reference

GB/T 13823 Vibration and shock sensors