E45-415 · Communication and Bus · Fiber Optic Module · ★★★
The fiber is bent to too small a radius during installation; long-term stress breaks the fiber core and communication is interrupted
[Mechanism] A bend radius below the minimum allowed puts lateral stress on the fiber core, creating micro-cracks that propagate to a full break over time.
[Calculation] A bend radius below 20 times the cable diameter sharply increases bending loss and concentrates stress; the fiber breaks and the optical path is interrupted.
[Design Deficiency] Installation did not follow the fiber's minimum bend radius.
① Bend control: bend radius ≥ 20 times the cable diameter → prevent fiber breakage
② Routing rules: use wide sweeping bends at turns → reduce stress
③ Protective conduit: run through conduit to prevent crushing → protect the fiber
④ Surplus coiling: coil the spare fiber in large loops → prevent kinking
⑤ Optical power monitoring: monitor optical power attenuation and alarm → early detection
⑥ Installation review: measure optical power and check break points at completion → early correction
⑦ Bend verification: measure loss after bending → data confirmation
⑧ Selection standardization: write the bend radius into the installation spec → control at the source
GB/T 13993.1-2014 Optical fibre cables for communication - Part 1: General