E45-316 · Calibration and Adjustment · Rotary Encoder · ★

Problem Description

The calibration direction is reversed; forward rotation gives a decreasing reading and positioning goes the wrong way

Root Cause

[Mechanism] The A/B phase wiring or the calibration direction setting is reversed, so the counting direction is opposite to the actual rotation direction and the position and speed signs are reversed.
[Calculation] Forward rotation should give +1000 pulses but gives -1000; the position accumulates in the reverse sense and the error grows with travel.
[Design Omission] No direction verification was done and the phase sequence was not checked.

Corrective Solution

① Direction verification: verify the direction by rotating before calibration → correct sign
② Phase-sequence check: check the A/B phase sequence → not reversed
③ Software setting: set the direction parameter correctly → consistent
④ Verification: run forward and reverse and compare → confirm symmetry
⑤ Out-of-tolerance alarm: warn on reversal → early warning
⑥ Records: keep the direction on file → traceability
⑦ Periodic calibration: calibrate every quarter → prevent drift
⑧ Write the direction requirement into the procedure → control at the source

Checklist

Reference

GB/T 29025-2012 General specification for pulse encoders