E45-340 · Environmental Protection and Temperature/Humidity · Pressure Sensor · ★★
During steam cleaning a sudden temperature change makes the sensor diaphragm and housing expand differently, cracking the seal and letting water in
[Mechanism] Different materials have different coefficients of thermal expansion; a sudden temperature change makes them expand out of step and generates thermal stress at the seal interface, and repeated cycling cracks the seal.
[Calculation] The expansion coefficient of the stainless-steel-to-glass seal differs by about 10ppm/℃; a sudden 80℃ change produces a strain of 800με that exceeds what the seal can take, cracking it.
[Design Omission] Selection did not consider thermal shock, and the seal design does not withstand thermal cycling.
① Matched expansion: choose sealing materials with matching expansion coefficients → reduce thermal stress
② Buffer structure: add an elastic buffer at the seal → absorb the expansion difference
③ Limited temperature ramp: raise and lower the cleaning temperature slowly → reduce the shock stress
④ Insulating transition: add an insulating sleeve to the probe → soften the thermal shock
⑤ Thermal-shock-rated selection: choose a sensor rated for thermal shock → increase margin
⑥ Seal monitoring: alarm when insulation <10MΩ → early warning of cracking and water ingress
⑦ Thermal-shock verification: run a thermal-shock cycling test to confirm → data confirmation
⑧ Selection standardization: write thermal-shock duty into the selection spec → control at the source
GB/T 2423.22-2012 Environmental testing for electric and electronic products - Test for temperature change