E45-177 · Grounding and Shielding · High-Frequency Sensor Shield Enclosure · ★
The sensor enclosure of a single-point-grounded 10MHz high-frequency signal radiates 30dB over the limit, disturbing a nearby receiver
[Mechanism] Single-point grounding works at low frequency, but at high frequency the ground lead's inductance and stray capacitance form a high impedance; the grounding impedance Z=2πfL rises with frequency, and at 10MHz a few meters of lead reaches ohms of inductive reactance, so the shield enclosure is no longer effectively grounded and becomes a floating antenna.
[Calculation] Lead inductance L=1μH/m over 2m → L=2μH; Z=2π×10⁷×2×10⁻⁶≈126Ω, far above the <0.1Ω required of PE → the enclosure potential floats with the radiation.
[Design Omission] The high-frequency equipment kept low-frequency single-point grounding, with no multi-point or 360° bonding.
① 360° bonding: bond the shield to the connector shell all around through an adapter ring → low-resistance continuous shielding
② High-frequency multi-point grounding: ground the enclosure every λ/20 (λ=30m at 10MHz → every 1.5m) → lowers the high-frequency impedance
③ Shorten the lead: keep the ground lead <λ/20 and use wide copper strap → reduces inductance
④ Shielded connector: use an EMI shielded connector to join shell to shell directly → does not break the shield
⑤ Enclosure to PE: clamp the enclosure directly to the PE bar → forces equipotential
⑥ Radiation prediction: simulate the enclosure potential <1V at 10MHz → verify it does not radiate
⑦ Radiation measurement: measure the radiation margin >6dB from 30-1000MHz with a receiver → verify compliance
⑧ Write the high-frequency grounding principle into the EMC design → gate at the source
GB/T 17626.3-2016 Radiated radio-frequency electromagnetic field immunity test