E45-426 · Vibration and Mechanical Stress · Accelerometer · ★★
The sensor mounting bracket's natural frequency is close to the equipment excitation frequency; resonance amplification makes the measured amplitude falsely high and distorted
[Mechanism] Insufficient bracket stiffness puts its natural frequency near the excitation frequency; resonance amplifies vibration transmissibility several times.
[Calculation] The bracket natural frequency of 50 Hz coincides with the equipment's 50 Hz excitation; transmissibility is amplified to 5 times, making readings falsely high.
[Design Deficiency] The bracket natural frequency was not checked against the excitation band.
① Raise stiffness: thicken the bracket to raise the natural frequency → avoid resonance
② Frequency check: bracket natural frequency ≥ 3× excitation → ensure isolation
③ Isolated mounting: add rubber isolation pads to cut transmission → suppress amplification
④ Finite element: model and simulate bracket modes → pre-empt frequency conflict
⑤ Damping dissipation: add damping material to lower the Q factor → cut peaks
⑥ Frequency response test: measure the frequency response curve after installation → data confirmation
⑦ Resonance verification: run a sweep test and check the amplification peak → data confirmation
⑧ Selection standardization: write bracket modes into the installation spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test