E45-042 · Cables and Drag Chains · 1mm² Power Drag Chain · ★★
A 1mm² power cable in the drag chain carries 15A, above its rated 10A; the temperature rises 40℃, the insulation thermally ages, and after one year it becomes brittle and cracks
[Mechanism] A conductor cross-section that is too small carrying above its rated current sharply increases Joule heating, and long-term overheating accelerates insulation aging and embrittlement.
[Calculation] The current density J=I/S=15/1=15A/mm² exceeds the recommended ≤6A/mm²; the temperature rise exceeds 40℃, and halving the life per 10℃ reduces it from 10 years to 2.5 years.
[Design Omission] The current-carrying capacity was not calculated, and the cross-section was not selected according to the current.
① Increase the cross-section: change to a 2.5mm² cable (carrying ≥20A) → current density drops from 15 to 6A/mm², temperature rise ≤15℃
② Current check: specify I≤6A/mm² in the selection table → eliminate overcurrent at the source
③ Temperature test: measure the cable temperature rise after installation (≤ rated) → confirm by measurement
④ Institutionalize: make the current-carrying capacity a mandatory item in the selection table → drawing gatekeeping
⑤ Heat dissipation: leave ventilation gaps in the drag chain (fill ≤50%) → helps heat dissipation
⑥ Inspection: check monthly whether the insulation has become brittle → catch progressive aging and replace early
⑦ Reduce the load: split into two supply paths to lower the per-cable current → if necessary
⑧ Maintenance: add to the quarterly check list → inspect periodically
GB/T 16895.15-2002 Low-voltage electrical installations