E45-051 · Cables and Drag Chains · Loose Ground on Shielded Cable · ★★
The shield's single-point grounding screw comes loose, raising the contact resistance from <1Ω to 20Ω; when the equipment vibrates, interference occasionally couples in and the reading jumps
[Mechanism] A single-point-grounded shield relies on a low-resistance connection to the enclosure to form a return path; a loose ground raises the contact resistance and lets the shield potential float, so noise couples in intermittently.
[Calculation] A 20Ω contact resistance raises the high-frequency shield impedance and lowers the shielding effectiveness by 15dB, and the contact makes and breaks as it loosens.
[Design Omission] No locking was provided on the ground point, and the contact resistance was not measured.
① Tighten: add a spring washer to the ground screw and lock it by torque (≥1.5N·m) → contact resistance <1Ω
② Locking: use a locknut or thread-locking adhesive → stays tight under vibration
③ Resistance test: measure the ground contact resistance after installation (<1Ω) → confirm by measurement
④ Institutionalize: make ground tightening a mandatory item in the wiring diagram → drawing gatekeeping
⑤ Jitter test: read the interference under vibration (≤0.2%) → confirm by measurement that nothing couples in
⑥ Dual grounding: provide redundant dual ground points on critical lines → if one loosens the other still connects
⑦ Inspection: check quarterly whether the ground has loosened → catch progressive loosening and retighten early
⑧ Maintenance: add to the quarterly check list → inspect periodically