E45-455 · Vibration and Mechanical Stress · Proximity Sensor · ★★
Vibration loosens and shifts the coil former of the inductive sensor; the inductance changes and the measuring distance deviates
[Mechanism] Vibration loosens the coil adhesive or shifts the former; the coil geometry changes and the inductance deviates from calibration.
[Calculation] A 0.2mm coil displacement changes the inductance by 2%, biasing the measuring distance by 0.5mm.
[Design Deficiency] The coil was not potted or fixed and relied only on adhesive.
① Potting: pot the coil as a whole → prevent movement
② Mechanical press fit: press-fit the former → stabilize the position
③ Adhesive reinforcement: add adhesive at the bond → strengthen
④ Vibration-resistant selection: choose a fully encapsulated inductor → improve stability
⑤ Periodic calibration: check the inductance deviation → early correction
⑥ Displacement monitoring: alarm on the zero point → early detection
⑦ Loosening verification: confirm by measuring inductance under vibration → data confirmation
⑧ Selection standardization: write coil fixing into the process spec → control at the source
GB/T 2423.10-2019 Environmental testing for electric and electronic products - Vibration test