E45-196 · Grounding and Shielding · Control-Signal Shielded Cable · ★
A shielded cable gives only 20dB of shielding effectiveness above 30MHz (over 60dB required), so high-frequency interference still couples in
[Mechanism] When the braid coverage is low, the gaps let the high-frequency field leak out and the shielding effectiveness SE falls as coverage drops; below 80% coverage the high-frequency (>30MHz) leakage becomes significant.
[Calculation] At coverage p=60%, SE≈(1-p)×SE_max; with a theoretical SE_max=80dB → actual SE≈32dB, matching the measured 20dB; over 90% coverage is needed to reach >60dB.
[Design Omission] A low-density braid shield was wrongly selected (insufficient coverage) and cannot meet the high-frequency SE requirement.
① High-density braid: select a shield with ≥90% braid coverage → SE>60dB
② Double shielding: overall braid shield + individual aluminum-foil shield → their gaps complement each other
③ Foil composite: add a longitudinally wrapped aluminum foil at 100% coverage → fills the braid gaps
④ 360° termination: clamp the shield all around at the connector → does not break the shield
⑤ High-frequency test: measure SE>60dB from 30-1000MHz → verify
⑥ Scenario check: choose the shield type according to the interference frequency → matches the cause
⑦ Continuous termination: the shield contacts the plug shell all around → low resistance
⑧ Write shielding specifications into cable selection → gate at the source
GB/T 17737.1-2013 Coaxial communication cables