E45-247 · Wiring and Terminals · Lead of Swinging Equipment · ★
Frequent robot motion broke the sensor lead at the terminal
[Mechanism] At the terminal the flexible wire takes the bending stress of the equipment's swing directly, with no strain relief; the copper strands at the bend fail by fatigue under the alternating stress.
[Calculation] With a swing angle of ±30° at 1Hz the bending strain at the terminal exceeds yield; the copper strands have a fatigue life of about 50,000 cycles and break, so the equipment failed within a month of running.
[Design Omission] No strain-relief bend, no cable chain, and no cushioning at the fixed point.
① Strain-relief bend: leave a slack loop before the terminal → absorb the swing
② Cable chain: run the lead in a cable chain → no bending
③ Cushioned fixing: add a sleeve at the fixed point → cushioning
④ Flexible cable: use high-flex cable → withstand bending
⑤ Bend radius: bend radius ≥10 times the cable diameter → no kinking
⑥ Motion test: verify by simulating the swing → confirmation
⑦ Break alarm: alarm immediately on a break → early warning
⑧ Write the strain relief into the drawing → control at the source
GB 50168-2018 Standard for construction and acceptance of cable line installation in electrical equipment installation engineering